260 research outputs found

    An ultrasonic technique for the measurement of elastic properties of soft surface coatings

    Get PDF
    The properties of thin layers of materials can be different from those in the bulk form. The response of a coating to any given load and its ability to remain bonded to the substrate will depend on its elastic modulus and Poisson's ratio. In this study a measurement method based on ultrasonic bulk wave reflection was evaluated. As a model system, a thin layer of polyethylene was pressed between two solid steel bodies. The reflection spectra of longitudinal and shear ultrasonic waves were recorded from the coating. The frequencies at which the layer resonates were measured and from this the wave speeds deduced. The Poisson's ratio can be determined from these two wave speeds and if the layer thickness is known the modulus is also available. The tests yielded reasonable values for both. This approach is only suitable if the layer can be made to resonate by the available ultrasonic frequencies; typically this will be the case for thicker coatings (tens of microns). Further, good coupling between the layer material and the steel bodies is necessary so that the interfaces do not themselves act to reflect ultrasound. This is better achieved with a smooth soft coating

    2,3-Dichloro-5,8-dimethoxy-1,4-naphthoquinone

    Get PDF

    Standard and Null Weak Values

    Full text link
    Weak value (WV) is a quantum mechanical measurement protocol, proposed by Aharonov, Albert, and Vaidman. It consists of a weak measurement, which is weighed in, conditional on the outcome of a later, strong measurement. Here we define another two-step measurement protocol, null weak value (NVW), and point out its advantages as compared to WV. We present two alternative derivations of NWVs and compare them to the corresponding derivations of WVs.Comment: 11 pages, 2 figures. To appear in Quantum Theory: A Two-Time Success Story: Yakir Aharonov Festschrif

    Weak Energy: Form and Function

    Full text link
    The equation of motion for a time-independent weak value of a quantum mechanical observable contains a complex valued energy factor - the weak energy of evolution. This quantity is defined by the dynamics of the pre-selected and post-selected states which specify the observable's weak value. It is shown that this energy: (i) is manifested as dynamical and geometric phases that govern the evolution of the weak value during the measurement process; (ii) satisfies the Euler-Lagrange equations when expressed in terms of Pancharatnam (P) phase and Fubini-Study (FS) metric distance; (iii) provides for a PFS stationary action principle for quantum state evolution; (iv) time translates correlation amplitudes; (v) generalizes the temporal persistence of state normalization; and (vi) obeys a time-energy uncertainty relation. A similar complex valued quantity - the pointed weak energy of an evolving state - is also defined and several of its properties in PFS-coordinates are discussed. It is shown that the imaginary part of the pointed weak energy governs the state's survival probability and its real part is - to within a sign - the Mukunda-Simon geometric phase for arbitrary evolutions or the Aharonov-Anandan (AA) phase for cyclic evolutions. Pointed weak energy gauge transformations and the PFS 1-form are discussed and the relationship between the PFS 1-form and the AA connection 1-form is established.Comment: To appear in "Quantum Theory: A Two-Time Success Story"; Yakir Aharonov Festschrif

    Diethyl 2-{[2-(trifluoro­meth­yl)anil­ino]methyl­idene}propane­dioate

    Get PDF
    The title compound, C15H16F3NO4, is an N-substituted derivative of ortho-trifluoro­methyl­aniline featuring a twofold Michael system. The least-squares planes defined by the atoms of the phenyl ring and the atoms of the Michael system enclose an angle of 15.52 (5)°. Apart from classical intra­molecular N—H⋯O and N—H⋯F hydrogen bonds, inter­molecular C—H⋯O contacts are observed, the latter connecting the mol­ecules into chains along [110]. The shortest inter­centroid distance between two aromatic systems is 3.6875 (9) Å

    Relativistic quantum clocks

    Full text link
    The conflict between quantum theory and the theory of relativity is exemplified in their treatment of time. We examine the ways in which their conceptions differ, and describe a semiclassical clock model combining elements of both theories. The results obtained with this clock model in flat spacetime are reviewed, and the problem of generalizing the model to curved spacetime is discussed, before briefly describing an experimental setup which could be used to test of the model. Taking an operationalist view, where time is that which is measured by a clock, we discuss the conclusions that can be drawn from these results, and what clues they contain for a full quantum relativistic theory of time.Comment: 12 pages, 4 figures. Invited contribution for the proceedings for "Workshop on Time in Physics" Zurich 201

    Ophthalmic magnetic resonance imaging at 7.0 T using a 6-channel transceiver radiofrequency coil array in healthy subjects and patients with intraocular masses

    Get PDF
    OBJECTIVES: This study was designed to examine the feasibility of ophthalmic magnetic resonance imaging (MRI) at 7.0 T using a local 6-channel transmit/receive radiofrequency (RF) coil array in healthy volunteers and patients with intraocular masses. MATERIALS AND METHODS: A novel 6-element transceiver RF coil array that makes uses of loop elements and that is customized for eye imaging at 7.0 T is proposed. Considerations influencing the RF coil design and the characteristics of the proposed RF coil array are presented. Numerical electromagnetic field simulations were conducted to enhance the RF coil characteristics. Specific absorption rate simulations and a thorough assessment of RF power deposition were performed to meet the safety requirements. Phantom experiments were carried out to validate the electromagnetic field simulations and to assess the real performance of the proposed transceiver array. Certified approval for clinical studies was provided by a local notified body before the in vivo studies. The suitability of the RF coil to image the human eye, optical nerve, and orbit was examined in an in vivo feasibility study including (a) 3-dimensional (3D) gradient echo (GRE) imaging, (b) inversion recovery 3D GRE imaging, and (c) 2D T2-weighted fast spin-echo imaging. For this purpose, healthy adult volunteers (n = 17; mean age, 34 +- 11 years) and patients with intraocular masses (uveal melanoma, n = 5; mean age, 57 +- 6 years) were investigated. RESULTS: All subjects tolerated all examinations well with no relevant adverse events. The 6-channel coil array supports high-resolution 3D GRE imaging with a spatial resolution as good as 0.2 × 0.2 × 1.0 mm, which facilitates the depiction of anatomical details of the eye. Rather, uniform signal intensity across the eye was found. A mean signal-to-noise ratio of approximately 35 was found for the lens, whereas the vitreous humor showed a signal-to-noise ratio of approximately 30. The lens-vitreous humor contrast-to-noise ratio was 8, which allows good differentiation between the lens and the vitreous compartment. Inversion recovery prepared 3D GRE imaging using a spatial resolution of 0.4 × 0.4 × 1.0 mm was found to be feasible. T2-weighted 2D fast spin-echo imaging with the proposed RF coil afforded a spatial resolution of 0.25 × 0.25 × 0.7 mm. CONCLUSIONS: This work provides valuable information on the feasibility of ophthalmic MRI at 7.0 T using a dedicated 6-channel transceiver coil array that supports the acquisition of high-contrast, high-spatial resolution images in healthy volunteers and patients with intraocular masses. The results underscore the challenges of ocular imaging at 7.0 T and demonstrate that these issues can be offset by using tailored RF coil hardware. The benefits of such improvements would be in positive alignment with explorations that are designed to examine the potential of MRI for the assessment of spatial arrangements of the eye segments and their masses with the ultimate goal to provide imaging means for guiding treatment decisions in ophthalmological diseases

    Quantum Optical Systems for the Implementation of Quantum Information Processing

    Get PDF
    We review the field of Quantum Optical Information from elementary considerations through to quantum computation schemes. We illustrate our discussion with descriptions of experimental demonstrations of key communication and processing tasks from the last decade and also look forward to the key results likely in the next decade. We examine both discrete (single photon) type processing as well as those which employ continuous variable manipulations. The mathematical formalism is kept to the minimum needed to understand the key theoretical and experimental results
    corecore